SH5.0/6.0/8.0/10RT

SH10RT Manual Published OND German Manual Published OND English Datasheet Published PDF English Whitepaper Published PDF German Whitepaper Published PDF German Whitepaper Published PDF German Whitepaper Published PDF English Whitepaper Published PDF English Whitepaper Published PDF English Whitepaper Published PDF Italian Datasheet Published PDF Italian Quick Installation Guide Published PDF English Quick Installation Guide Published PDF English Datasheet Published PDF German Datasheet Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF German Certificate Published PDF German Certificate Published PDF German Certificate Published PDF English Datasheet Published PDF English

FLEXIBLE APPLICATION

 

  • 150~600V wide battery voltage range
  • Supports parallel connection with full communication between inverters
  • Provides fully unbalanced loads

 

SMART MANAGEMENT

  • High self-consumption with optimised built-in EMS
  • Free online monitoring to enhance energy management for end user, installer and retailer
  • Remote firmware update and customisable settings

ENERGY INDEPENDENCE

  • Seamless transition to backup mode for protection against power outages
  • Fast charging/discharging to meet the demand of higher consumption and energy trading

EASY INSTALLATION

  • Unique push-in connectors for time-saving installation
  • Touch free commissioning with smartphone
  • Lightweight and compact
Australia Europe Residential

SG2K/2K5/3K-S

.. Datasheet Published PDF German Datasheet Published PDF English Datasheet Published PDF French Datasheet Published PDF Italian Manual Published PDF German Manual Published PDF English Manual Published PDF Spanish Manual Published PDF French Manual Published PDF Italian Manual Published PDF Dutch Manual Published PDF Portuguese Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF German Certificate Published PDF German Certificate Published PDF French Certificate Published PDF French Certificate Published PDF English Certificate Published PDF Dutch Certificate Published PDF Italian Certificate Published PDF Italian Datasheet Published PDF Polish Quick Installation Guide Published PDF English Datasheet Published PDF Dutch Datasheet Published PDF Spanish Certificate Published PDF English Datasheet Published PDF English

HIGH YIELD

  • Industry leading efficiency of 98.4%
  • Flexible PV string configurations
  • High DC/AC ratio up to 1.3

SMART MANAGEMENT

  • Feature-rich online monitoring via App or Web
  • Firmware updates & new monitoring features
  • Gain energy flow with Sungrow smart meter

SAFE AND RELIABLE

  • Built-in surge arresters & RCD
  • Cutting-edge technology ensures long life time
  • High anti-corrosion rating at C5

EASY INSTALLATION

  • Unique push-in connectors for time-saving installation
  • Mounting plate with built-in level
  • Fast and easy commissioning via App or LCD
Europe Brasil (PT) Residential
DC reverse connection protection
No
AC short-circuit protection
No
Leakage current protection
No
DC switch
No
AC switch
No
PV string current monitoring
No
PID recovery function
No
Arc fault circuit interrupter (AFCI)
No
Islanding Protection
No
PV reverse connection protection
No
DC main output load switch
Off
PV specific application SPD
Off
PV SPD failure monitoring
Off
PV self power supply for internal loads
Off
Communication port
Off
Current and voltage monitoring for each string
Off
English

SG3K6-D/SG4K-D/SG4K6-D/SG6K-D

.. Datasheet Published PDF English Datasheet Published PDF Spanish Datasheet Published PDF Italian Datasheet Published PDF Portuguese Manual Published PDF German Manual Published PDF English Manual Published PDF Spanish Manual Published PDF French Manual Published PDF Italian Manual Published PDF Dutch Manual Published PDF Portuguese Quick Manual Published PDF English Certificate Published PDF Italian Certificate Published PDF Italian Certificate Published PDF Dutch Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF German Certificate Published PDF German Certificate Published PDF French Certificate Published PDF French Certificate Published PDF English Datasheet Published PDF Polish Datasheet Published PDF English Datasheet Published PDF Dutch Certificate Published PDF English Datasheet Published PDF English

High Yield

  • Industry leading efficiency of 98.4%
  • Flexible PV string configurations
  • High DC/AC ratio up to 1.3

Safe and Reliable

  • Built-in surge arresters & RCD
  • Cutting-edge technology ensures long life time
  • High anti-corrosion rating at C5

Smart Management

  • Feature-rich online monitoring via App or Web
  • Firmware updates & new monitoring features
  • Gain energy flow with Sungrow smart meter

Easy Installation

  • Unique push-in connectors for time-saving installation
  • Mounting plate with built-in level
  • Fast and easy commissioning via App or LCD
Australia Global Headquarters Europe Brasil (PT) Residential
Max. operating altitude
4000 m (> 2000 m derating)
Max. PV input voltage
600V
Min. PV input voltage / Startup input voltage
90 / 120 V
MPP voltage range for nominal power
90 V – 560 V | 210 V – 480 V | 240 V – 480 V 260 V – 480 V 315 V – 480 V
No. of independent MPP inputs
2
Max. PV input current
20 A (10 A / 10 A)
Max. AC output power
3680 VA | 4000 VA2) / 4600 VA | 6000 VA
AC voltage range
180 – 276 Vac
Nominal grid frequency / Grid frequency range
50 Hz / 60 Hz / 45 – 55 Hz / 55 – 65 Hz
THD
< 3 % (of nominal power)
DC current injection
< 0.5 % (of nominal current)
Power factor at nominal power / Adjustable power factor
0.99 / 0.8 leading – 0.8 lagging
Feed-in phases / Connection phases
1/1
Cooling method
Natural cooling
Allowable relative humidity range (non-condensing)
0 – 100 %
Display
LCD
Nominal AC voltage
230 Vac
Isolation method
transformerless
Night power consumption
< 1 W**
Nominal input voltage
360 V
Max. number of PV strings per MPPT
1
Max. current for input connector
24 A (12 A / 12 A)
DC reverse connection protection
No
AC short-circuit protection
Yes
Leakage current protection
Yes
DC switch
Yes
AC switch
No
PV string current monitoring
Yes
PID recovery function
No
Arc fault circuit interrupter (AFCI)
No
Islanding Protection
No
PV reverse connection protection
Yes
DC main output load switch
Off
PV specific application SPD
Off
PV SPD failure monitoring
Off
PV self power supply for internal loads
Off
Communication port
Off
Current and voltage monitoring for each string
Off
Dimensions (W x H x D)
360 × 390 × 133 mm 14.1732 × 15.3543 × 5.23622 in
English

SG3K-D / SG5K-D - Premium

.. Manual Published PDF English

High Yield

  • Higher yield with Max. efficiency 98.4 %, European efficiency 98.0 %
  • 12.5 A MPPT current, and compatible with  bifacial modules
  • Flexible PV string configurations, DC/AC ratio up to 1.4 

Safe and Durable

  • Quick Arc Fault Circuit Interrupter
  • Built-in Type II DC&AC surge protection device
  • Built-in certified PV isolator

Smart Management

  • 24H real-time loads monitoring
  • Easy local and online monitoring via App or Web

Easy and User Friendly

  • 11.5 kg compact design, plug and play installation
  • Fast commissioning via App
Australia Residential
Max. operating altitude
4000 m (> 2000 m derating)
Max. PV input voltage
600V
Min. PV input voltage / Startup input voltage
90 V / 120 V
MPP voltage range for nominal power
260 V – 480 V
Max. PV input current
25 A (12.5 A / 12.5 A)
AC voltage range
180 Vac – 276 Vac
Nominal grid frequency / Grid frequency range
50 Hz / 60 Hz / 45 – 55 Hz / 55 – 65 Hz
THD
< 3 % (of nominal power)
Power factor at nominal power / Adjustable power factor
0.99 / 0.8 leading – 0.8 lagging
Feed-in phases / Connection phases
1/1
Cooling method
Natural cooling
Allowable relative humidity range (non-condensing)
0 – 100 %
Display
LCD
Nominal AC voltage
230 Vac
Isolation method
transformerless
Max. DC short-circuit current
30 A (15 A / 15 A)
Night power consumption
< 3 W
Nominal input voltage
360 V
Max. number of PV strings per MPPT
2
DC reverse connection protection
No
AC short-circuit protection
Yes
Leakage current protection
Yes
DC switch
Yes
AC switch
No
PV string current monitoring
Yes
PID recovery function
No
Arc fault circuit interrupter (AFCI)
No
Islanding Protection
No
PV reverse connection protection
Yes
DC main output load switch
Off
PV specific application SPD
Off
PV SPD failure monitoring
Off
PV self power supply for internal loads
Off
Communication port
Off
Current and voltage monitoring for each string
Off
Nominal AC output power
4999 VA
Nominal AC output current
21.7 A
PV connection type
MC4 (max. 6 mm²)
Certifications
IEC62109-1, IEC62109-2, IEC62116, IEC61727, EN 61000-6-2, EN 61000-6-3, AS / NZS 4777.2
Dimensions (W x H x D)
360 × 390 × 133 mm 14.1732 × 15.3543 × 5.23622 in
English

SG5/6KTL-MT | SG8/10/12KTL-M

.. Datasheet Published PDF Polish Datasheet Published PDF English Datasheet Published PDF English Datasheet Published PDF German Manual Published PDF English Quick Installation Guide Published PDF English Datasheet Published PDF Dutch Datasheet Published PDF Spanish Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF English Certificate Published PDF German Certificate Published PDF German Certificate Published PDF English Certificate Published PDF French Certificate Published PDF Italian Certificate Published PDF Dutch Certificate Published PDF Spanish Certificate Published PDF English Certificate Published PDF English Datasheet Published PDF English Datasheet Published PDF English Datasheet Published PDF German Datasheet Published PDF Polish Datasheet Published PDF Italian Certificate Published PDF English Certificate Published PDF Polish Certificate Published PDF Polish Certificate Published PDF Polish Certificate Published PDF Polish Certificate Published PDF Polish Certificate Published PDF Polish Certificate Published PDF Polish Certificate Published PDF Polish Datasheet Published PDF English Datasheet Published PDF English

High Yield

  • Max. efficiency 98.6%, European efficiency 98.0%
  • 1.1 overload capacity, 10% more yield under high irradiance
  • Adapt to complex power grid, extend the grid-connected generation time

Safe and Reliable

  • High power quality, no interference for electrical equipment
  • Low radiation, compliance with household equipment standards
  • High anti-corrosion with aluminum alloy die casting
  • Built-in surge arresters and residual current protection

Easy O&M

  • 20kg, easy O&M
  • Plug and play design, easy installation
  • String current monitoring function for fast trouble shooting
  • Fast commissioning, easy local and on-line monitoring
Australia Asia & Pacific Europe Residential
Max. operating altitude
4000 m (> 3000 m derating)
Max. PV input voltage
1100 V
Min. PV input voltage / Startup input voltage
200 V / 250 V
MPP voltage range for nominal power
240 – 850 V | 290 – 850 V |. 380 – 850 V
No. of independent MPP inputs
2
Max. PV input current
22 A (11 A / 11 A)
Max. AC output power
5500 VA @ 35 °C / 5000 VA @ 45 °C | 6.6 kVA @ 35 ℃ / 6.0 kVA @ 45 ℃ | 8.8 kVA @ 35 ℃ / 8.0 kVA @ 45 ℃
Max. AC output current
8.5 A | 10.0 A | 13.3 A
AC voltage range
270 V – 480 V
Nominal grid frequency / Grid frequency range
50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz
THD
< 3 % (at nominal power)
DC current injection
< 0.5 % In
Power factor at nominal power / Adjustable power factor
> 0.99 / 0.8 leading – 0.8 lagging
Feed-in phases / Connection phases
3 / 3
Cooling method
Natural cooling
Allowable relative humidity range (non-condensing)
0 – 100 %
Display
LED
Nominal AC voltage
3 / N / PE, 230 / 400 V
Isolation method
Transformerless
Max. DC short-circuit current
30 A (15 A / 15 A)
Night power consumption
< 1 W
Notices
Devices for Australia are not equipped with DC switches
Nominal input voltage
600 V
Max. number of PV strings per MPPT
1
Max. current for input connector
15 A
DC reverse connection protection
Yes
AC short-circuit protection
Yes
Leakage current protection
Yes
DC switch
Yes
AC switch
Yes
PV string current monitoring
Yes
PID recovery function
No
Arc fault circuit interrupter (AFCI)
No
Islanding Protection
Yes
PV reverse connection protection
No
DC main output load switch
Off
PV specific application SPD
Off
PV SPD failure monitoring
Off
PV self power supply for internal loads
Off
Communication port
Off
Current and voltage monitoring for each string
Off
Dimensions (W x H x D)
370 × 160 × 485 mm
English

SH5K-30

.. Datasheet Published PDF English Manual Published PDF English

Flexible Application

  • Convenient for new installation and retrofit
  • Compatible with both lithium-ion and lead-acid batteries
  • Energy trading ready with 3rd-party EMS to maximize ROI

Smart Management

  • High self-consumption with optimized built-in EMS
  • Free online monitoring to enhance energy management for end user, installer, and retailer
  • Remote firmware update and customizable settings

Safe and Reliable

  • Built in surge arresters and residual current protection
  • Durable finish with high anti-corrosion enclosure

Easy Installation

  • Cleaner and simpler install with EPS built-in to inverter
  • Custom-fit mounting play with built-in level
  • Fast and easy commissioning via front panel LCD or APP
Australia Europe Residential
Max. operating altitude
2000m
Max. PV input voltage
600 V
Min. PV input voltage / Startup input voltage
125 V
MPP voltage range for nominal power
240 V – 520 V
No. of independent MPP inputs
2
Max. PV input current
22 A (11 A / 11 A)
Max. AC output power
5000 VA
Max. AC output current
22.7 A
AC voltage range
176 Vac~276 Vac
Nominal grid frequency / Grid frequency range
50 Hz / 60 Hz / 45~55 Hz / 55~65 Hz (this may vary with grid standards)
THD
<3 % (of nominal power)
DC current injection
<0.5 % (of nominal current)
Power factor at nominal power / Adjustable power factor
>0.99 at default value at nominal power (adj. 0.8 overexcited / leading to 0.8 underexcited / lagging)
Cooling method
Natural convection
Allowable relative humidity range (non-condensing)
0%~100%
Display
Graphic LCD
Nominal AC voltage
220 Vac / 230 Vac / 240 Vac
Isolation method
Isolation method (solar), Isolation method (battery) / Transformerless, HF
Max. DC short-circuit current
24 A (12 A / 12 A)
Nominal input voltage
350 V
Max. number of PV strings per MPPT
1 / 1
Max. current for input connector
12 A
DC reverse connection protection
No
AC short-circuit protection
Yes
Leakage current protection
Yes
DC switch
No
AC switch
No
PV string current monitoring
No
DC fuse
DC switch (solar) DC fuse (battery) / Optional, Yes
PID recovery function
No
Arc fault circuit interrupter (AFCI)
No
Islanding Protection
Yes
Additional information
Battery type
Li-ion battery / Lead-acid battery
Battery voltage
48 V (32 V–70 V)
Max. charge / discharge current
65 A / 65 A
Power management
1 × Digital Output
Earth alarm
Email, buzzer inside
Pv connection type
MC4
PV reverse connection protection
No
DC main output load switch
Off
PV specific application SPD
Off
PV SPD failure monitoring
Off
PV self power supply for internal loads
Off
Communication port
Off
Current and voltage monitoring for each string
Off
Dimensions (W x H x D)
457 × 515 × 170 mm 17.9 × 20.2 × 6.69 in
English

SBP4K8 | BATTERY

.. Datasheet Published PDF English

Innovative and Reliable

  • High reliability and safety with prismatic cells from Samsung
  • Robust BMS provides multi-protection at both cell level and system level
  • Over 95% depth of discharge to maximise the usable capacity

Intelligent Management

  • Remote monitoring of battery status with App and web portal
  • Smart hibernation technology to maintain battery state of health

Easy Installation

  • Suitable for both free-standing and wall-mountable installation
  • Simple setup for multiple batteries
  • One-click online firmware update
Australia Residential
DC reverse connection protection
No
AC short-circuit protection
No
Leakage current protection
No
DC switch
No
AC switch
No
PV string current monitoring
No
PID recovery function
No
Arc fault circuit interrupter (AFCI)
No
Islanding Protection
No
PV reverse connection protection
No
DC main output load switch
Off
PV specific application SPD
Off
PV SPD failure monitoring
Off
PV self power supply for internal loads
Off
Communication port
Off
Current and voltage monitoring for each string
Off
English

SH3K6/SH4K6

.. Datasheet Published PDF German Datasheet Published PDF English Datasheet Published PDF French Datasheet Published PDF Dutch Quick Installation Guide Published PDF English Quick Installation Guide Published PDF Italian Manual Published PDF German Manual Published PDF English Manual Published PDF French Manual Published PDF Italian Manual Published PDF Dutch Certificate Published PDF English Certificate Published PDF English Datasheet Published PDF Italian Certificate Published PDF Italian Certificate Published PDF Italian Certificate Published PDF Italian Certificate Published PDF Italian Datasheet Published PDF English

Smart and Integrated

  • Integrated optimized energy management system, batter usage strategies and smart home load control
  • Energy trading ready with external EMS to maximize payback on your investment
  • Monitoring via smartphone or laptop, providing email reports and alerts. 

Safe and Durable

  • Integrated high-frequency isolated batter charge/discharge circuit
  • Protection rating at IP65 (dust-proof and water-proof)

Flexible Application

  • For both new installation and retrofitting solar systems
  • Compatible with both lithium-ion and lead acid batteries

Simple and User Friendly

  • Easy commissioning and customizable settings via LCD
  • Auto-identification of lithium-ion batteries
  • One-click firmware update via Wi-Fi or ethernet, easy for maintenance and management
Europe Residential
Max. operating altitude
2000 m
Max. PV input voltage
600 V
Min. PV input voltage / Startup input voltage
125 V
MPP voltage range for nominal power
180 V – 520 V | 220 V – 520 V
No. of independent MPP inputs
2
Max. PV input current
22 A (11 A / 11 A)
Max. AC output power
3680 W | 4600 W
Max. AC inverter output current
16 A | 20 A
AC voltage range
180 Vac – 276 Vac (this may vary with grid standards)
Nominal grid frequency / Grid frequency range
50 Hz / 45 Hz – 55 Hz (this may vary with grid standards)
THD
< 3 % (of nominal power)
DC current injection
< 0.5 % (of nominal power)
Power factor at nominal power / Adjustable power factor
> 0.99 at default value at nominal power (adj. 0.8 overexcited/ leading–0.8 underexcited/lagging)
Cooling method
Natural convection
Allowable relative humidity range (non-condensing)
0 %–100 %
Display
Graphic LCD
Nominal AC voltage
230 Vac
Isolation method
Transformerless
Night power consumption
< 1 W
Nominal input voltage
360 V
Max. number of PV strings per MPPT
1 / 1
Max. current for input connector
12 A
DC reverse connection protection
No
AC short-circuit protection
Yes
Leakage current protection
Yes
DC switch
Yes
AC switch
No
PV string current monitoring
No
CEC efficiency
94.00 %
DC fuse
DC fuse (Solar) - No | DC fuse (battery) - Yes
PID recovery function
No
Arc fault circuit interrupter (AFCI)
No
Islanding Protection
Yes
PV reverse connection protection
No
DC main output load switch
Off
PV specific application SPD
Off
PV SPD failure monitoring
Off
PV self power supply for internal loads
Off
Communication port
Off
Current and voltage monitoring for each string
Off
Max. PV input power
6500 W
Nominal AC output power
3680 W | 4600 W
Power Management
1 × Digital Output
Earth Alarm
1 × Digital Output, email, buzzer inside
PV connection type
MC4
Battery Voltage
48 V (32 V–70 V)
Max. charge / discharge current
65 A / 65 A
Battery Brand
Li-ion battery / Lead-acid battery
Short circuit current of PV input
24 A (12 A / 12 A)
Certifications
VDE-AR-N-4105, DIN VDE0126-1-1, G83/2, G59/3, CEI 0-21, IEC 62109-1, IEC62109-2, EN 62477-1, EN 61000-6-1/-3
Dimensions (W x H x D)
457 × 515 × 170 mm 17.9 × 20.2 × 6.6 in
English

SH5K-20

.. Datasheet Published PDF English

Mounting Method - Wall-mounting bracket

Flexible Application

  • Convenient for new installation and retrofit
  • Compatible with both lithium-ion and leadacidbatteries
  • Energy trading ready with 3rd-party EMS to maximize ROI

Smart Management

  • High self-consumption with optimised built-in EMS
  • Free online monitoring to enhance energy management for end user, installer and retailer
  • Remote firmware update and customisable settings

Safe and Reliable

  • Built-in surge arresters and residual current protection
  • Durable finish with high anti-corrosion enclosure

Easy Installation

  • Custom-fit mounting plate with built-in level
  • Fast and easy commissioning via front panel LCD or App
  • Lightweight and compact
Australia Europe Residential
Max. operating altitude
2000m
Max. PV input voltage
600 V
Min. PV input voltage / Startup input voltage
125 V
MPP voltage range for nominal power
240 V – 520 V
No. of independent MPP inputs
1
Max. PV input current
22 A (11 A / 11 A)
Max. AC output current
21.7 A
AC voltage range
180 Vac~276 Vac (this may vary with grid standards)
Nominal grid frequency / Grid frequency range
50 Hz / 45~55 Hz (this may vary with grid standards)
THD
<3 % (of nominal power)
DC current injection
<0.5 % (of nominal current)
Power factor at nominal power / Adjustable power factor
>0.99 at default value at nominal power (adj. 0.8 overexcited / leading to 0.8 underexcited / lagging)
Cooling method
Natural convection
Allowable relative humidity range (non-condensing)
0%~100%
Display
Graphic LCD
Nominal AC voltage
230 Vac
Isolation method
Transformerless (Solar) | HF (Solar)
Max. DC short-circuit current
24 A (12 A / 12 A)
Nominal input voltage
350 V
Max. number of PV strings per MPPT
1 / 1
Max. current for input connector
24 A (12 A / 12 A)
DC reverse connection protection
No
AC short-circuit protection
Yes
Leakage current protection
Yes
DC switch
Yes
AC switch
No
PV string current monitoring
No
DC fuse
YES
PID recovery function
No
Arc fault circuit interrupter (AFCI)
No
Islanding Protection
Yes
Additional information
PV Connection Type
buzzer inside
AC connection type
Clamping yoke connector
Earth Alarm
MC4
Power Management
1 × Digital Output
Communication
2 × RS485, Wi-Fi , CAN, Ethernet
PV reverse connection protection
No
DC main output load switch
Off
PV specific application SPD
Off
PV SPD failure monitoring
Off
PV self power supply for internal loads
Off
Communication port
Off
Current and voltage monitoring for each string
Off
Max. PV input power
6500 W
Nominal AC output power
4990 W
Nominal AC output current
21.6 A
Dimensions (W x H x D)
457 × 515 × 170 mm 18 × 20.2 × 6.69 in
English