Logger1000

.. Datasheet Published PDF English

Flexible Networking

  • Support of RS485, Ethernet, WiFi communication
  • Support of energy meter, meteo station, sensors and other equipment access

Convenient O&M

  • Inverter batch parameter setting and firmware updates
  • Plant maintenance by remote Web access, optimized OPEX
  • Active and reactive power control
  • Local monitoring

Easy Operation

  • Automatic Modbus address distribution
  • Built-in Web server for monitoring and configuration, by PC or smartphone browser, no APP required
Australia Asia & Pacific Europe Monitoring
DC reverse connection protection
No
AC short-circuit protection
No
Leakage current protection
No
DC switch
No
AC switch
No
PV string current monitoring
No
PID recovery function
No
Arc fault circuit interrupter (AFCI)
No
Islanding Protection
No
Additional information
Protection class
IP20
PV reverse connection protection
No
Operating temperature
-30 °C ~ 60 °C
Operating humidity
≤95 % (non-condensing)
DC main output load switch
Off
PV specific application SPD
Off
PV SPD failure monitoring
Off
PV self power supply for internal loads
Off
Communication port
Off
Current and voltage monitoring for each string
Off
Max. number of devices
30
RS485 interface
3
Ethernet
1×RJ45, 10/100/1000 Mbps
Digital input
5, Max. 24V DC
Analog input
4, support 4~20 mA or 0~10 VDC
4G communication
LTE(FDD): B1, B3, B5, B8 LTE(TDD): B38, B39, B40, B41 TD-SCDMA: B34, B39 CDMA: BC0 GSM:900MHz / 1800MHz WCDMA:B1, B8"
WiFi communication
802.11 b / g / n / ac HT20 / 40 / 80M Hz 2.4G Hz / 5G Hz
DC input
24 VDC, 1.2 A
DC output
24 VDC, 0.5 A
Power consumption
<10 W
Elevation
≤4000 m
Logger1000A
Support 4G and WiFi wireless communication Apply to China, India, Malaysia
Logger1000B
Support WiFi only wireless communication Apply to Global
Dimensions (W x H x D)
200 × 110 × 60 mm 7.87 × 4.33 × 2.36 in
English

iSolarCloud

.. Datasheet Published PDF English Manual Published PDF English Datasheet Published OND Spanish

Flexible and Friendly

  • Centralized PV plant management, low O&M cost
  • User-defined performance views, full plant supervision via muti-dimensional analysis
  • Flexible data access, Web portal & APP

Simple and Efficient

  • Simple Network infrastructure, fast platform deployment
  • Real time fault analysis and report
  • Quick trouble shooting

Safe and Reliable

  • Hierarchical access management
  • Redundant data storage over the lifecycle of your plants
Australia Asia & Pacific Europe Brasil (PT) Japan Monitoring

E-Net

.. Datasheet Published PDF English Quick Manual Published PDF English Certificate Published PDF English

Smart and Flexible

  • Supporting DHCP, and automatic network transmission without configuration
  • Applicable to scenarios in which wireless communication is inaccessible

Simple and Efficient

  • Supporting remote operation and maintenance functions including remote upgrading, parameter setting
  • Plug and play, quick installation

Safe and Reliable

  • Wire transmission, stable and reliable
  • IP65, wide temperature range
Australia Asia & Pacific Europe Monitoring

WiFi

WiFi Datasheet Published PDF English Datasheet Published PDF Spanish Quick Manual Published PDF English Certificate Published PDF English Certificate Published PDF English

Smart and Flexible

  • Supporting mainstream WLAN networking protocols, with favourable compatibility

Simple and Efficient

  • Supporting remote operation and maintenance functions including remote upgrading, parameter setting
  • Supporting direct connection configuration with APP, quickly and easily
  • Plug and play, quick installation
  • Professional design in wireless communication, and high quality signal
  • IP65, wide temperature range
Australia Asia & Pacific Europe Latin America (ESP) Monitoring

EyeM4

..
Datei
EyeM4.pdf
Datasheet Published PDF English Quick Manual Published PDF Chinese Quick Manual Published PDF English

Simple and Flexible

  • One-click access to iSolarCloud
  • One module can manage up to 10 inverters for remote maintenance and control
  • Plug and play, easy installation

Convenient O&M

  • Built-in Web server for monitoring and configuration, by PC or smartphone browser; no APP required
  • Support of plant maintenance by remote Web access, optimized OPEX
  • Support of local and remote parameter setting and firmware updates
Australia Asia & Pacific Europe Monitoring
Notices
EyeM4A: Support of 4G and WiFi wireless communication, for China, India, Malaysia
EyeM4B: Support of 4G wireless communication, for China
EyeM4C: Support of WiFi wireless communication, for global application

COM100

.. Datasheet Published PDF English

Smart and Flexible

  • Flexible installation with wall-mounted, column-mounted and floor-standing method

Simple and Efficient

  • Seamless connection to iSolarCloud for easier central management of PV plants

Safe and Reliable

  • Electrical isolation and lightening protection equipped for each terminals to ensure the reliable communication
Monitoring

PVM1000(Japan)

.. Datasheet Published PDF English

Smart and Flexible

  • Insight integrated (monitoring software), monitoring of
  • devices such as inverters, combiner boxes, transformers,
  • power conversion systems
  • Integrated fibre switch, convenient and flexible
  • networking

Simple and Efficient

  • Applicable to 200 MW utility scale power plants
  • Seamless connection to iSolarCloud and easy centralized
  • management of power plants

Safe and Reliable

  • Equipped with hardware firewall
Europe Japan Monitoring
DC reverse connection protection
No
AC short-circuit protection
No
Leakage current protection
No
DC switch
No
AC switch
No
PV string current monitoring
No
PID recovery function
No
Arc fault circuit interrupter (AFCI)
No
Islanding Protection
No
PV reverse connection protection
No
Number of optical fiber ports
4, 8, 16, or 24
Number of Ethernet ports
8, 16, or 20
Firewall
Optional
Communication medium network method
Optical fiber, Ethernet bus / fiber ring. | Communication protocol: IEC104 master / slave
Power supply
200~240 VAC, 32 A, and 50 Hz
Operating temperature
-20 °C~60 °C (IPC) / 10 °C ~ 35 °C (Server)
Operating humidity
≤95 % (25 °C)
Monitoring software
Insight
Server
IPC / Server
Workstation
Desktop computer
DC main output load switch
Off
PV specific application SPD
Off
PV SPD failure monitoring
Off
PV self power supply for internal loads
Off
Communication port
Off
Current and voltage monitoring for each string
Off
Dimensions (W x H x D)
600 × 2,000 × 1,000 mm 23.6 × 78.7 × 39.3 in
English

THREE-PHASE ENERGY METER DTSD1352-C/10(80)A

.. Europe Monitoring
AC voltage range
3 x 180/311 V ... 3 x 268/464 V
Nominal grid frequency / Grid frequency range
-25 °C ... +55 °C
Nominal AC voltage
3 x 230/400 V
DC reverse connection protection
No
AC short-circuit protection
No
Leakage current protection
No
DC switch
No
AC switch
No
PV string current monitoring
No
PID recovery function
No
Arc fault circuit interrupter (AFCI)
No
Islanding Protection
No
PV reverse connection protection
No
Environment humidity (non-condensing)
0 % ... 95 %
DC main output load switch
Off
PV specific application SPD
Off
PV SPD failure monitoring
Off
PV self power supply for internal loads
Off
Communication port
Off
Current and voltage monitoring for each string
Off
Dimensions (W x H x D)
89 × 127 × 70 mm 3.5 × 5 × 2.75 in
English

Logger1000

.. Datasheet Published PDF English

Flexible networking

  • Support of RS485, Ethernet, WiFi communication
  • Support of energy meter, meteo station, sensors and other equipment access

Convenient O&M

  • Inverter batch parameter setting and firmware updates
  • Plant maintenance by remote Web access, optimized OPEX
  • Active and reactive power control
  • Local monitoring

Easy Operation

  • Automatic Modbus address distribution
  • Built-in Web server for monitoring and configuration, by PC or smartphone browser, no APP required
Europe Monitoring
DC reverse connection protection
No
AC short-circuit protection
No
Leakage current protection
No
DC switch
No
AC switch
No
PV string current monitoring
No
PID recovery function
No
Arc fault circuit interrupter (AFCI)
No
Islanding Protection
No
PV reverse connection protection
No
Operating temperature
-30 °C ~ 60 °C
Protection class
IP20
DC main output load switch
Off
PV specific application SPD
Off
PV SPD failure monitoring
Off
PV self power supply for internal loads
Off
Communication port
Off
Current and voltage monitoring for each string
Off
Max. number of devices
30
RS485 interface
3
Ethernet
1×RJ45, 10/100/1000 Mbps
Digital input
5, Max. 24V DC
Analog input
4, support 4~20 mA or 0~10 VDC
4G communication
LTE(FDD): B1, B3, B5, B8 LTE(TDD): B38, B39, B40, B41 TD-SCDMA: B34, B39 CDMA: BC0 GSM:900MHz / 1800MHz WCDMA:B1, B8"
WiFi communication
802.11 b / g / n / ac HT20 / 40 / 80M Hz 2.4G Hz / 5G Hz
DC input
24 VDC, 1.2 A
DC output
24 VDC, 0.5 A
Power consumption
<10 W
Elevation
≤4000 m
Logger1000A
Support 4G and WiFi wireless communication Apply to China, India, Malaysia
Logger1000B
Support WiFi only wireless communication Apply to Global
Relative air humidity
≤95 % (non-condensing)
Dimensions (W x H x D)
60 × 200 × 110 mm 2.36 × 7.88 × 4.33 in
English